Binary logistic regression analyses for predicting postprocedural hypotension after carotid artery stenting
Parameter | OR | 95% CI | P value |
Conventional calcification location | |||
Distance from carotid bifurcation to maximum stenotic lesion | 0.867 | 0.810 to 0.928 | <0.001* |
Stent type | 1.753 | 1.091 to 2.816 | 0.020* |
Presence of calcification | 4.088 | 0.802 to 20.837 | 0.090 |
Number of quadrants involved in calcification | 2.136 | 1.317 to 3.466 | 0.002* |
Calcification on the dorsal side | 0.966 | 0.430 to 2.169 | 0.933 |
Modified calcification location | |||
Distance from carotid bifurcation to maximum stenotic lesion | 0.859 | 0.799 to 0.923 | <0.001* |
Stent type | 1.767 | 1.079 to 2.892 | 0.024* |
Presence of calcification | 3.715 | 0.696 to 19.821 | 0.124 |
Number of quadrants involved in calcification | 1.938 | 1.140 to 3.294 | 0.015* |
Calcification on the interior side | 0.693 | 0.219 to 1.650 | 0.408 |
Calcification on the exterior side | 0.679 | 0.277 to 1.661 | 0.396 |
Calcification on the dorsal side | 3.520 | 1.497 to 8.274 | 0.004* |
*Indicates statistical significance (p<0.05).
CI, confidence interval; OR, odds ratio.